Replacing or adding voice processing boards

Standard 1.10

M1/CS1000 switch connectivity

There are two valid configurations for MPB96 boards with M1/CS1000 switch connectivity. The following table shows valid configurations.

Table 14: MPB96 with M1/CS1000 switch

MPB96 boards

Slot number

Max. channels

MPU

 

 

 

 

1

1

96

96

3 (high capacity)

1, 2, 3

192

288

 

 

 

 

Determine which configuration applies to your system.

ATTENTION You must use one of the valid configurations for the system to function properly.

Taking safety precautions

Before you make any changes to the server hardware, follow these safety precautions:

„

„

„

„

Respect appropriate electrostatic discharge (ESD) rules.

Power down the system.

Do not drop and leave screws inside the server.

Do not drop hard objects (such as screwdrivers) inside the server as this can damage the server.