RAID operations Standard 1.10
150 CallPilot
1Restart the server and enter the Ctrl+M utility when prompted
during system bootup.
2From the Management menu, select Objects and press Enter.
3Select Objects > Physical Drive and press Enter.
4Select FAIL Drive for the drive that is online (A01-1-Onln).
Result: The drive shows as failed.
5Select the second drive (previously taken offline as the backup drive
and marked failed) and make it ONLINE. Ignore the warning
message.
Result: The second drive is marked ONLINE and the first drive is
marked failed.
6Exit the utility and press Ctrl+Alt+Delete to reboot the server.
Result: The system boots up to the original configuration before the
PEP installation.
7When the system is fully booted, open the Windows MegaRAID
console and rebuild the failed drive using the same process
described in “To synchronize the RAID after a successful PEP
installation,” on page 149.
Result: The system is now in the original configuration.
ATTENTION Do not use the Power Console for the following procedure,
or data corruption can occur.