RAID operations

Standard 1.10

ATTENTION

Do not use the Power Console for the following procedure,

 

 

or data corruption can occur.

1Restart the server and enter the Ctrl+M utility when prompted during system bootup.

2From the Management menu, select Objects and press Enter.

3Select Objects > Physical Drive and press Enter.

4Select FAIL Drive for the drive that is online (A01-1-Onln). Result: The drive shows as failed.

5Select the second drive (previously taken offline as the backup drive and marked failed) and make it ONLINE. Ignore the warning message.

Result: The second drive is marked ONLINE and the first drive is marked failed.

6Exit the utility and press Ctrl+Alt+Delete to reboot the server.

Result: The system boots up to the original configuration before the PEP installation.

7When the system is fully booted, open the Windows MegaRAID console and rebuild the failed drive using the same process described in “To synchronize the RAID after a successful PEP installation,” on page 149.

Result: The system is now in the original configuration.

150

CallPilot

Page 150
Image 150