RAID operations

Standard 1.10

If the firmware is not correct, perform a firmware update. For instructions, see “To upgrade or downgrade the RAID firmware” on page 140.

To upgrade or downgrade the RAID firmware

The firmware of the RAID card is upgraded through a flash process. The flash process is initiated by running the RAID card firmware update utility on the CallPilot DVD.

ATTENTION

WARNING

Perform this procedure only if the firmware version is not the version identified in this section.

Nortel strongly recommends that you not perform low level formatting. Performing low level formatting results in the drives becoming unusable.

1Insert the CallPilot Image DVD for the platform into the DVD combo drive.

2Power down the CallPilot server.

3Restart the CallPilot server.

Result: The server boots from the DVD and the Startup Menu appears.

1.Install CallPilot server image for 1005r and boot (recommended)

2.Install CallPilot server image for 1005r and exit to DOS

3.Utilities (BIOS, Firmware, etc...)

4Enter 3 to run Utilities (BIOS, Firmware, etc...) from the Startup. Result: The Nortel CallPilot Image Menu appears.

1.1005r server BIOS update

140

CallPilot

Page 140
Image 140
Nortel Networks 1005r manual To upgrade or downgrade the RAID firmware