Troubleshooting your CallPilot system Standard 1.10
32 CallPilot
Interpreting BIOS error messages
When a recoverable error occurs during the POST, an error message
appears describing the problem.

BIOS error messages

BIOS error messages appear on the video monitor. Refer to the following
table for a description of the messages.

Table 3: BIOS error messages

ATTENTION If BIOS error messages appear, record the error messages
and then call Nortel technical support before attempting to
correct the problem.
Error message Description
GA20 Error An error occurred with Gate A20 when
switching to protected mode during the
memory test.
Pri Master HDD Error
Pri Slave HDD Error
Sec Master HDD Error
Sec Slave HDD Error
Could not read sector from
corresponding drive.
ATAPI Incompatible Drive
Pri Master Drive
Pri Slave Drive
Sec Master Drive
Sec Slave Drive
The corresponding drive is not an
ATAPI (Advanced Technology
Attachment Packet Interface) device.
Run Setup to make sure the device is
selected correctly.