June 2007 RAID operations
1005r Server Maintenance and Diagnostics 143
3From the Objects menu, select Adapter and press Enter.
4From the Adapter menu, select Factory Default.
5Select Yes to confirm the selection and press Enter.
6Press Ctrl+Alt+Delete when prompted to restart system.
7During bootup, press Ctrl+M to re-enter the RAID setup utility.
8From the Management menu, select Objects Adapter, and then
ensure the Adapter 1 values are set as follows:
Flex RAID Power Fail: Enabled
Fast Initialization: On
Disk Spin up Timing: 1 Disk every 6 secs
Cache Flush Timings: Every 4 seconds
Rebuild Rate: 30%
Alarm Control: Enabled (There is no audible alarm)
Other Adapter Options:
— Emulation: Mass Storage
— Auto Rebuild: Disabled
— Initiator ID: 7
— Cluster Mode: Disabled
— Multiple PCI Delayed Transactions: Disabled
— Force Boot: On
— Coercion Algorithm: GigaByte Way
— Cc Restoration: Enabled
Note: The Coercion Algorithm must be set properly. When
changed, it cannot be changed again without clearing the
configuration.
9From the Configuration menu, select New Configuration. Click Yes
to proceed.
Result: The system displays the SCSI channel with two drives.
SCSI IDs are automatically assigned for each of the two drives. All
disk drives must be in READY state.
Note: Do not use the Load command on the Configure menu. This
command is not for RAID operations.
10 Create the logical drive by selecting Channel-1 A01-0 and pressing
the spacebar.