Contents of the Setup Mode

This section describes the contents of the setup mode.

No

Item

Description

SelectableDefault
parameters

 

 

 

 

 

 

 

 

 

 

 

Specifies the double feed detection. Double

 

 

1

Double feed check

feed is detected by checking the document

No/Yes

No

 

 

length and/or paper thickness.**

 

 

 

 

 

 

 

 

Length check

Specifies the document length to enable

Tolerance:

 

2

double feed detection sets the document

No

=No/10/15/20 mm

No/10/15/20mm

 

length.

 

 

 

 

 

 

 

 

 

 

 

 

Scanner automatically sets the

Document:

 

 

 

No

 

 

 

recommended reading parameters. 3 sets

 

3

IPC pre-setting

1: Sharpen

No

of parameters are available when IPC-4D is

 

 

not installed.

2: Darken Character

 

 

 

3: Copy Quality

 

 

 

 

 

 

 

 

 

 

4

Resetting of

Resets the abrasion counter.

---

---

abrasion counter

 

 

 

 

 

 

 

 

 

 

Pick start time

Specifies the time from document Insertion

Time:

 

5

to the start of picking. User can select the

1.0 sec

setting

0.2 to 29.8 sec

 

most comfortable Pick start time for the job.

 

 

 

 

 

 

 

 

 

 

 

 

Specifies the time the scanner waits for the

Time:

 

6

Time-out limit setting

next document insertion after the last

27 values from

30 sec

 

 

document was scanned.

1 to 1999 sec

 

 

 

 

 

 

 

ADF front offset

Specifies the horizontal and vertical offset

Offset:

Offset:

7

H:-2 to +3 mm

H: 0 mm

setting*

of the front side image when using the ADF.

 

 

 

V:-2 to +3 mm

V: 0 mm

 

ADF back offset

Specifies the horizontal and vertical offset

Offset:

Offset:

8

of the back side image when using the

H:-2 to +3 mm

H: 0 mm

setting*

 

ADF.

V:-2 to +3 mm

V: 0 mm

 

 

 

 

 

 

 

 

Flatbed offset

Horizontal and vertical offset of the FB

Offset:

Offset:

9

H:-2 to +3 mm

H: 0 mm

setting*

image is specified.

 

V:-2 to +3 mm

V: 0 mm

 

 

 

 

 

 

 

 

10

IPC status display

Displays whether or not the image

---

---

processing board (IPC-4D) is installed.

 

 

 

 

 

 

 

 

 

 

 

The SCSI ID is selectable. Note that the

SCSI ID:

 

11

SCSI ID setting

new setting is made valid after power is

5

0/1/2/3/4/5/6/7

 

 

turned off and on again.

 

 

 

 

 

 

 

 

 

 

12

SCSI terminator

Switches the SCSI terminator On/Off.

On/Off

On

 

setting

 

 

 

13

Low Power Mode

Changes the default setting of the duration

5 min.

15 min.

 

setting

for power save.

to 60 min.

 

7-2