13. Low Power Mode Setting

<Screen 53>

1Press “Next” or “Previous” and let the

scanner display Screen 53.

2At Screen 53, press or to select the time duration. A minimum of 5 min to the

maximum of 60 minutes can be selected.

Then press to activate the setting.

NOTICE

The default time recommended by the ENERGYSTAR® program is 15 minutes. The default for the fi-4750C scanner is 15 minutes, as recommended.

3Press to return.

14. Select Interface

<Screen 54>

1Press “Next” or “Previous” and let the

scanner display Screen 54.

NOTICE

The screen 54 will appear oniy when the scanner has proper interface boards or option boards in the third party slot.

2At Screen 54, press or to select the

interface type. Press if you want to change the setting.

NOTICES

1.Normally, this setting does not have to be changed.

2.When an appropriate board is installed in the third party slot of the scanner, the scanner automatically turns off the SCSI interface, activating the board in the third party slot. Screen 54 can be used to forcibly change the selected interface. The selected interface is then forcibly changed.

3.The SCSI interface and the board installed in the third party slot cannot be used at the same time.

4.The default is Auto.

3 Press to return.

7-11