Turn on the scanner before cleaning the following locations, and rotate the rollers to clean them thoroughly.
•Feed rollers (x 2)
Clean lightly taking care not to scratch the surface of the rollers. Take particular care in cleaning the feed rollers since black debris on the rollers adversely affect the feed performance.
•Eject rollers (x 2)
Clean lightly taking care not to scratch the surface of the rollers. Take particular care in cleaning the eject rollers since black debris on the rollers adversely affect the feed performance.
When the ADF cover is open and the [SCAN] button is held down, pressing the [POWER] button once will rotate the Feed and Eject rollers by a certain angle.
Generally speaking, six presses of the [POWER] button make the rollers rotate one full turn.
SCAN
POWER
12 DUPLEX COLOR
1.While holding down the [SCAN] button....
2. ...press the [POWER] button.
⇒The rollers rotate.
ATTENTION
Power the scanner only when cleaning the feed rollers and eject rollers. Unplug the scanner for futher cleaning.
82