6.2 Error Indications in the Operator Panel (1)

1 2

When any error occurrs, the operator panel indicates "U" followed by a number for temporary errors or "E" followed by a number for device alarms (permanent error). Temporary errors can be resolved by the operator, but the device alarm requires recovery works by support engineers.

When the Error Recovery Guide is installed on your PC, its window appears when Windows is started up. If any error or device alarm occurred, this software displays information such as error names and error codes regarding the error/ alarm. Record the information and click [Details] on its window to learn detailed information for trouble shooting.

Temporary Errors :

Indication

U0

U1

U2

U4

Meaning

Shipping lock error(fi-5220C only)

Paper Feed Error

Multi Feed Error

The ADF has been opened during scanning.

Remedy

Confirm that the shipping lock is released. For details refer toA[fi-5120C/fi-5220C Getting Start section 2.1 Installing the Scanner].

Remove the jammed documents. Refer to " 6.1

Removing JammedDocuments".

Confirm that the documents meet the paper conditions for scanning. Refer to "7.2

Document Quality".

Close the ADF cover completely. For the details, refer to "6 TROUBLESHOOTING".

U6 The print cartridge is not set.(fi-5120C only)

This is a temporary error related withthe Imprinter option (sold separately). For details refer to 553PR Operator's Guide, chapter "5 Error Message".

HINT

The Error Recover Guide is stored in Setup CD-ROM. When installing the application software, refer to "2.1 Installing the Scanner Application" in fi-5120C/fi-5220C Getting Started.

1 2