Appendix 3 REPLACING CONSUMABLES
| During its operation, the inside |
| |
glass of the ADF becomes very | |
| hot. |
| Before replacing the |
| consumables, turn its power off |
| and unplug the AC adapter from |
| the outlet. Wait at least |
15minutes.
■Consumables and Replacement Cycle
The followings are the specifications of consumables and their recommended replacement cycles.
The following illustrations show the locations of the consumables. Refer to "5. REPLACEMENT OF CON- SUMABLES" in the
SETUP
Pick roller | Separator roller |
|
Pad
Brake roller
Description | Parts No. | Standard | |
Replacement Cycle | |||
|
| ||
|
|
| |
|
|
| |
Pad | PA03450- | After 600,000 scans or | |
| K014 | one year | |
|
|
| |
Pick rollers | PA03450- | After 600,000 scans or | |
| K011 | one year | |
|
|
| |
Brake roller | PA03450- | After 600,000 scans or | |
| K013 | one year | |
|
|
| |
Separator | PA03450- | After 600,000 scans or | |
rollers | K012 | one year |
To purchase consumables, contact the store where you purchased the scanner or an authorized FUJITSU scanner service provider.
The replacement cycles above are rough guidelines
when scanning A4/Letter sized, 80 g/m2 [20lb] paper. This cleaning cycle varies according to the type of papers scanned and how frequently the scanner is used and cleaned.
ATTENTION | Use only the specified consumables. |
■Pad
To remove
Pad
To install