Hardware Installation and Service Issues
This section describes hardware specific issues and workarounds.
Specific Issues and Workarounds
TABLE 1 lists known hardware issues and possible workarounds.
TABLE 1 Hardware Issues and Workarounds
CR ID | Description | Workaround |
|
|
|
6433420 The domain console might display a Mailbox timeout or IOCB interrupt timeout error during boot.
6488846 During boot, the domain console might display a checksum error for the SG(X)PCI2SCSIU320‐ Z SCSI controller I/O card.
6498780 On the SPARC Enterprise M4000/M5000 servers, the OpenBoot. PROM (OBP) might not detect the on‐board disk (HDD) boot device. Performing a boot disk results in a console message:
Can’t locate boot device
Issue a
Check for the availability of the latest controller card firmware.
The PCI or PCI‐X plug‐in adapter card might not be seated correctly. Reseat the card in slot 0 of the IOU.