TABLE 6 Specific Issues and Workarounds Concerning Solaris (Continued)

CR ID

Description

Workaround

 

 

 

6530753 Some of the PCI slots in the External I/O Expansion Unit PCI slots are not displayed during a normal boot operation.

6531036 The error message network initialization failed appears repeatedly after a boot net installation.

6531668 System hangs when executing parallel hotplug operation with SP DR in suspend phase.

6532215 volfs or dscp service may fail when domain is booted.

svc:/platform/sun4u/dscp:default: Method "/lib/svc/method/svc-dscp start" failed with exit status 95.

svc:/system/filesystem/volfs:defaul

t:Method or service exit timed out. Killing contract 59.

6534471 Domain may panic.

6535564 PCI hot plug to PCI slot #0, #1 or External IO Expansion Unit may fail on XSB added by DR.

Use one of the following operations to display all of the PCI slots.

boot -r(at open boot prompt)

devfsadm -C(at Solaris prompt)

cfgadm (twice at Solaris prompt)

No workaround available at this time. Ignore the messages.

No workaround available at this time.

Restart the service if the failure is observed. To avoid the problem, issue the following commands.

#svccfg -s dscp setprop start/timeout_seconds=count: 300

#svccfg -s volfs setprop start/timeout_seconds=count: 300

#svcadm refresh dscp

#svcadm refresh volfs

Add the following line to /etc/system and reboot the domain.

set heaplp_use_stlb=0

There is no workaround. Use DR instead of PCI hot plug if need to add or remove PCI card on the XSB.

SPARC Enterprise M4000/M5000 Servers Product Notes 29