TABLE 6 Specific Issues and Workarounds Concerning Solaris (Continued)

CR ID

Description

Workaround

 

 

 

6502204 Unexpected error messages may be displayed on console on booting after CPU UE panic.

Example:

SUNW-MSG-ID: FMD-8000-11, TYPE:

Defect, VER: 1, SEVERITY: Minor

EVENT-TIME: Tue Jan 9 20:45:08 JST 2007

PLATFORM: SUNW,SPARC-Enterprise,

CSN: 2030636002, HOSTNAME: P2-DC1- 16-d0

6502750 Notification message for inserted or removed card by PCI hotplug may not output.

6505921 Correctable error on the system PCIe bus controller generates an invalid fault.

6508432 Many correctable errors (CE) may occur, and despite these are the correctable errors, domain may panic.

6508434 The domain may panic when an additional PCI‐X card is installed or a PCI‐X card is replaced by using PCI hot plug.

6509337 s10s_u3 wanboot failes ‐ The server returned 416: Requested Range Not Satisfiable.

6510779 On a large single domain configuration, the system may incorrectly report very high load average at times.

6510861 When Dual‐Channel Ultra320 SCSI Card (SE0X7SC2F,SE0X7SC2X) is mounted, correctable errors(CE) occur and system may panic.

6511374 Unexpected error messages may be displayed on console after changing the system configuration.

Example:

WARNING: Translation error source /LSB0/B0/0, PA 3c000000000, target /LSB0/B0/20000000

If you see unexpected messages, check system status on XSCF.

None available at this time.

Create a file /etc/fm/fmd/fmd.conf

containing the following lines;

setprop client.buflim 40m

setprop client.memlim 40m

Set the following to /etc/system and then reboot the domain:

set pcie:pcie_aer_ce_mask = 0x2001

Do not insert a different type of PCI‐X card on the same PCI slot card by using PCI hotplug.

None available at this time.

There is no workaround. Check for the availability of a patch for this defect.

To mask these errors with Dual‐Channel Ultra320 SCSI Card (SE0X7SC2F,SE0X7SC2X), add the following entry to the /etc/system file and then reboot the system:

set pcie:pcie_aer_ce_mask = 0x31c1

This message can be safely ignored.

SPARC Enterprise M4000/M5000 Servers Product Notes 27