TABLE 6 Specific Issues and Workarounds Concerning Solaris (Continued)
CR ID | Description | Workaround |
|
|
|
6496337 The ʺcpumem‐diagnosisʺ module may fail to load after uncorrectable error(UE) panic.
Systems will function correctly but events normally automatically diagnosed by FMA using this module will require manual diagnosis.
Example:
Defect, VER: 1, SEVERITY: Minor
PLATFORM:
CSN: BE80601007, HOSTNAME:
6498283 Using the DR deleteboard command while psradm operations are running on a domain might cause a system panic.
6499304 CPU isnʹt offlined and unexpected message is displayed on console when many correctable error(CE) occurs.
Example:
Defect, VER: 1, SEVERITY: Minor
PLATFORM:
BE80601035, HOSTNAME:
If problem occurred, implement the following workaround:
1.Remove the following file.
#rm /var/fm/fmd/ckpt/cpumem-
2.Restart fmd service.
#svcadm restart fmd
To avoid this problem in advance, add ʺrm ‐f /var/fm/fmd/ckpt/cpumem‐ diagnosis/cpumem‐diagnosisʺin /lib/svc/method/svc‐dumpadm file as below.
#
#We haven't run savecore on a dump device yet
savedev=none
rm
#
There is no workaround. Check for the availability of a patch for this defect.
Check CPU status on XSCF.