TABLE 6 Specific Issues and Workarounds Concerning Solaris (Continued)

CR ID

Description

Workaround

 

 

 

6496337 The ʺcpumem‐diagnosisʺ module may fail to load after uncorrectable error(UE) panic.

Systems will function correctly but events normally automatically diagnosed by FMA using this module will require manual diagnosis.

Example:

SUNW-MSG-ID: FMD-8000-2K, TYPE:

Defect, VER: 1, SEVERITY: Minor

EVENT-TIME: Thu Feb 15 15:46:57 JST 2007

PLATFORM: SUNW,SPARC-Enterprise,

CSN: BE80601007, HOSTNAME: col2-ff- em7-d0

6498283 Using the DR deleteboard command while psradm operations are running on a domain might cause a system panic.

6499304 CPU isnʹt offlined and unexpected message is displayed on console when many correctable error(CE) occurs.

Example:

SUNW-MSG-ID: FMD-8000-11, TYPE:

Defect, VER: 1, SEVERITY: Minor

EVENT-TIME: Fri Feb 2 18:31:07 JST 2007

PLATFORM: SPARC-Enterprise, CSN:

BE80601035, HOSTNAME: FF2-35-0

If problem occurred, implement the following workaround:

1.Remove the following file.

#rm /var/fm/fmd/ckpt/cpumem- diagnosis/cpumem-diagnosis

2.Restart fmd service.

#svcadm restart fmd

To avoid this problem in advance, add ʺrm ‐f /var/fm/fmd/ckpt/cpumem‐ diagnosis/cpumem‐diagnosisʺin /lib/svc/method/svc‐dumpadm file as below.

#

#We haven't run savecore on a dump device yet

savedev=none

rm -f /var/fm/fmd/ckpt/cpumem- diagnosis/cpumem-diagnosis

#

There is no workaround. Check for the availability of a patch for this defect.

Check CPU status on XSCF.

26 SPARC Enterprise M4000/M5000 Servers Product Notes for XCP Version 1041 • July 2007