TABLE 7 Documentation Updates (Continued)
Title | Page Number |
| Update | |
|
|
|
|
|
SPARC Enterprise | 2.5 "Operation Management" | |||
M4000/M5000/M8000/ |
| The following sections will be added: | ||
M9000 Servers Dynamic |
| 2.5.6, "XSCF Failover" | ||
Reconfiguration (DR) |
| |||
| An XSCF failover might prevent a DR operation from | |||
User's Guide |
| |||
| completing. To check, log in to the active XSCF, check the status | |||
|
| |||
|
| of the system board and, if necessary, repeat the DR operation. | ||
|
| 2.5.7, "Kernel Memory Board Deletion" | ||
|
| If an XSCF failure or failover occurs during the | ||
|
| phase of a deleteboard(8) or moveboard(8) operation, the | ||
|
| Solaris OS may panic and display the following message: | ||
|
|
|
|
|
|
|
| Irrecoverable FMEM error error_code |
|
|
|
|
|
|
|
| If you see this message, log in to the XSCF again to check status. | ||
|
| You may have to reboot the Solaris OS and, on the XSCF, check | ||
|
| system board status, specify the kernel memory board, and | ||
|
| repeat the DR operation. | ||
|
| 2.5.8, "Deletion of Board with DVD Drive" | ||
|
| To delete the system board to which the server's DVD drive is | ||
|
| connected, execute the following steps: | ||
|
| 1. Stop the vold(1M) daemon by disabling the volfs service. | ||
|
|
|
| |
|
|
| # /usr/sbin/svcadm disable volfs |
|
|
|
|
|
|
|
| 2. Execute the DR operation. | ||
|
| 3. Restart the vold(1M) daemon by enabling the volfs service. | ||
|
|
|
| |
|
|
| # /usr/sbin/svcadm enable volfs |
|
|
|
|
|
|
|
| For details, see the vold(1M) Solaris man page. | ||
|
|
|
|
|
28 SPARC Enterprise M4000/M5000 Servers Product Notes for XCP Version 1041 • October 2007