TABLE 7 Documentation Updates (Continued)

Title

Page Number

 

Update

 

 

 

 

 

SPARC Enterprise

2-27

2.5 "Operation Management"

M4000/M5000/M8000/

 

The following sections will be added:

M9000 Servers Dynamic

 

2.5.6, "XSCF Failover"

Reconfiguration (DR)

 

 

An XSCF failover might prevent a DR operation from

User's Guide

 

 

completing. To check, log in to the active XSCF, check the status

 

 

 

 

of the system board and, if necessary, repeat the DR operation.

 

 

2.5.7, "Kernel Memory Board Deletion"

 

 

If an XSCF failure or failover occurs during the Copy-rename

 

 

phase of a deleteboard(8) or moveboard(8) operation, the

 

 

Solaris OS may panic and display the following message:

 

 

 

 

 

 

 

 

Irrecoverable FMEM error error_code

 

 

 

 

 

 

 

 

If you see this message, log in to the XSCF again to check status.

 

 

You may have to reboot the Solaris OS and, on the XSCF, check

 

 

system board status, specify the kernel memory board, and

 

 

repeat the DR operation.

 

 

2.5.8, "Deletion of Board with DVD Drive"

 

 

To delete the system board to which the server's DVD drive is

 

 

connected, execute the following steps:

 

 

1. Stop the vold(1M) daemon by disabling the volfs service.

 

 

 

 

 

 

 

# /usr/sbin/svcadm disable volfs

 

 

 

 

 

 

 

 

2. Execute the DR operation.

 

 

3. Restart the vold(1M) daemon by enabling the volfs service.

 

 

 

 

 

 

 

# /usr/sbin/svcadm enable volfs

 

 

 

 

 

 

 

 

For details, see the vold(1M) Solaris man page.

 

 

 

 

 

28 SPARC Enterprise M4000/M5000 Servers Product Notes for XCP Version 1041 • October 2007