Solaris Issues and Workarounds

TABLE 6 lists known issues and possible workarounds.

TABLE 6 Specific Issues and Workarounds Concerning Solaris

CR ID

Description

Workaround

 

 

 

6348554

Using the cfgadm -c disconnect

There is no workaround. Check for the

 

command on the following cards might hang

availability of a patch for this defect.

 

the command during i_mdi_pi_offline:

 

 

SG-XPCIE2FC-QF4 Sun StorageTek

 

 

Enterprise Class 4Gb Dual-Port Fibre

 

 

Channel PCI-E HBA

 

 

SG-XPCIE1FC-QF4 Sun StorageTek

 

 

Enterprise Class 4Gb Single-Port Fibre

 

 

Channel PCI-E HBA

 

 

SG-XPCI2FC-QF4 Sun StorageTek Enterprise

 

 

Class 4Gb Dual-Port Fibre Channel PCI-X

 

 

HBA

 

 

SG-XPCI1FC-QF4 Sun StorageTek Enterprise

 

 

Class 4Gb Single-Port Fibre Channel PCI-X

 

 

HBA

 

6416224

System performance can degrade using a

Use multiple NIC cards to split network

 

single NIC card with more than 5,000

connections.

 

connections.

 

6440061 The domain console may display this message:

ipsec_check_inbound_policy: Policy Failure for the incoming packet (not secure)

6441349 The system may hang if there is an I/O error in the system.

6459540 The DAT72 internal tape drive on SPARC Enterprise M4000/M5000 may time out during tape operations.

This message can be safely ignored.

None available at this time.

Add the following definition to /kernel/drv/st.conf:

tape-config-list =

"SEAGATE DAT DAT72-000",

"SEAGATE_DAT____DAT72-000", "SEAGATE_DAT____DAT72-000"; SEAGATE_DAT____DAT72-000= 1,0x34,0,0x9639,4,0x00,0x8c,0x8c, 0x8c,3;

There are four spaces between SEAGATE DAT and DAT72-00.

16 SPARC Enterprise M4000/M5000 Servers Product Notes for XCP Version 1041 • October 2007