TABLE 6 Specific Issues and Workarounds Concerning Solaris (Continued)

CR ID

Description

Workaround

 

 

 

6572593 fmdump(1M) may show wrong faulty component when IOU hardware error occurs.

6589833 The DR addboard command might cause a system hang if you are adding a Sun StorageTek Enterprise Class 4Gb Dual-Port Fibre Channel PCI-E HBA card (SGXPCIE2FC- QF4) at the same time that an SAP process is attempting to access storage devices attached to this card. The chance of a system hang is increased if the following cards are used for heavy network traffic:

X4447A-Z, PCI-e Quad-port Gigabit Ethernet Adapter UTP

X1027A-Z1, PCI-e Dual 10 Gigabit Ethernet Fiber XFP Low profile Adapter

6592302 Unsuccessful DR operation leaves memory partially configured.

Check system status on XSCF.

There is no workaround. Check for the availability of a patch for this defect.

To recover, add the board back to the domain with the addboard command, then retry the

deleteboard command.