TABLE 6 Specific Issues and Workarounds Concerning Solaris (Continued)
CR ID | Description | Workaround |
|
|
|
6496337 The
Systems will function correctly but events normally automatically diagnosed by FMA using this module will require manual diagnosis.
Example:
Defect, VER: 1, SEVERITY: Minor
PLATFORM:
CSN: BE80601007, HOSTNAME:
6498283 Using the DR deleteboard(8) command while psradm operations are running on a domain might cause a system panic.
6499304 CPU isn't offlined and unexpected message is displayed on console when many correctable error(CE) occurs.
Example:
Defect, VER: 1, SEVERITY: Minor
PLATFORM:
BE80601035, HOSTNAME:
If problem occurred, implement the following workaround:
1.Remove the following file.
#rm /var/fm/fmd/ckpt/cpumem-
2.Restart fmd service.
#svcadm restart fmd
To avoid this problem in advance, add "rm
#
#We haven't run savecore on a dump device yet
savedev=none
rm
#
There is no workaround. Check for the availability of a patch for this defect.
Check CPU status on XSCF.
18 SPARC Enterprise M4000/M5000 Servers Product Notes for XCP Version 1041 • October 2007