TABLE 2 Documentation Updates (Continued)

Title

Page Number

 

Update

 

 

 

 

 

SPARC Enterprise

9-1

CHAPTER 9, "XSCF Unit Replacement"

 

M4000/M5000 Servers

15-1

CHAPTER 15, "Operator Panel Replacement"

 

Service Manual

 

The following important message will be added.

 

 

 

 

 

 

 

 

 

 

 

 

Note – If you replace the XSCF unit and the operator

 

 

 

 

panel simultaneously, system will not operate normally.

 

 

 

 

Execute the showhardconf command or the

 

 

 

 

showstatus command to confirm that the component

 

 

 

 

replaced earlier is operating normally, before replacing

 

 

 

 

the subsequent FRU.

 

 

 

 

 

 

SPARC Enterprise

11-7

11.2, "DIMM Replacement"

 

M4000/M5000 Servers

 

See “DIMM Replacement” on page 11 for the changes.

 

Service Manual

 

 

 

 

SPARC Enterprise

C-7

TABLE C-5 "Power Supply Feature"

 

M4000/M5000 Servers

 

See “Electrical Specifications” on page 9 for the changes.

 

Service Manual

 

 

 

 

Electrical Specifications

The following changes belong in the SPARC Enterprise M4000/M5000 Servers Service Manual.

TABLE 3 Power Supply Features

 

SPARC Enterprise M4000

SPARC Enterprise M5000

 

 

 

Power draw (maximum)

2016W

3738W

Volt Ampere

2058 VA

3815 VA

Heat

6879 BTUs/hr (7258 kJ/hr)

12754 BTUs/hr (13457 kJ/hr)

 

 

 

SPARC Enterprise M4000/M5000 Servers Product Notes 9