Fujitsu MAU3147NC/NP, MAU3073NC/NP, MAU3036NC/NP manual Error rate, Reliability

Models: MAU3036NC/NP MAU3147NC/NP MAU3073NC/NP

1 130
Download 130 pages 55.01 Kb
Page 31
Image 31
2.1.4Error rate

(*4) At power-off state after installation

Vibration displacement should be less than 2.5 mm.

(*5) Input voltages are specified at the drive connector side, during drive ready state.

(*6) The terminator power pin (SCSI connector) which supplies power to other terminators is not used (See Section 4.3).

(*7) High frequency noise (over 20 MHz) is less than 100 mVp-p.

2.1.4Error rate

Errors detected during initialization and replaced by alternate block assignments are not included in the error rate. Data blocks to be accessed should be distributed over the disk medium equally.

(1)Unrecoverable error rate

Errors which cannot be recovered within 63 retries and ECC correction should not exceed 1 per 1015 bits.

2.1.5ReliabilityCAUTION

Data loss

The drive adopts Reed-Solomon code for ECC. The sector-data is divided into 3 interleaving sectors, and ECC is performed in each sector where the maximum number of errors (up to 9 byte) can be corrected. [Total maximum byte: 9 byte 3 ( interleave) = 27 byte] If the error of read sector keeps allowable error byte number, correction is performed. However, if error byte exceeds its allowable number, correction may not be performed properly.

(2)Positioning error rate

Positioning errors which can be recovered by one retry should be 10 or less per 108 seeks.

2.1.5Reliability

(1)Mean Time Between Failures (MTBF)

MTBF of the IDD during its life time is 1,2000,000 hours (operating: 24 hours/day, 7 days/week

average DE surface temperature: 50°C or less).

Note:

The MTBF is defined as:

Operating time (hours) at all field sites

MTBF=

The number of equipment failures from all field sites

C141-E205

2-5

Page 31
Image 31