Fujitsu MAU3073NC/NP, MAU3147NC/NP manual 3 CN2 setting terminal on NP models only, SCSI ID setting

Models: MAU3036NC/NP MAU3147NC/NP MAU3073NC/NP

1 130
Download 130 pages 55.01 Kb
Page 78
Image 78
Figure 5.3 CN2 setting terminal (on NP models only)

2 4 6 8 10 12 14 16 18 20 22 24

1 3 5 7 9 11 13 15 17 19 21 23

Terminator power supply: Supply (LED signal)

(IDD Reset signal) N.C.

Force Single Ended: LVD mode

Force Narrow: 16-bit SCSI

Motor start mode

Write protect: enabled

SCSI ID #15

Figure 5.3 CN2 setting terminal (on NP models only)

5.3.1SCSI ID setting

Table 5.1 shows the SCSI ID setting. For the terminal location and allocation of NC model, see Figure 4.13 and Table B.1. For NP model, see Figure 5.2 and 5.3.

IMPORTANT

When the SCSI ID is set using the external operator panel connector CN1 of NP model, all pins listed in Table 5.1 should be open. If any of pins are shorted, unexpected SCSI ID is set.

5-6

C141-E205

Page 78
Image 78
Fujitsu MAU3073NC/NP, MAU3147NC/NP, MAU3036NC/NP manual 3 CN2 setting terminal on NP models only, SCSI ID setting