Alert message

Page

 

 

 

Mounting Installation

Damage

 

 

1.

Be careful of the insertion orientation of the SCSI connectors.

5-12

 

 

With the system in which terminating resistor power is supplied

 

 

 

via the SCSI cable, if the power is turned on, the overcurrent

 

 

 

protection fuse of the terminating resistor power supplier may

 

 

 

be blown or the cable may be burnt if overcurrent protection is

 

 

 

not provided.

 

 

 

When the recommended parts listed in Table 4.2 are used,

 

 

 

inserting the cables in the wrong direction can be prevented.

 

 

2.

To connect SCSI devices, be careful of the connection position

 

 

 

of the cable. Check that the SCSI device with the terminating

 

 

 

resistor is the last device connected to the cable.

 

 

Data loss

 

 

When the SEND DIAGNOSTIC command terminates with the

6-4

 

CHECK CONDITION status, the INIT must collect the error

 

 

information using the REQUEST SENSE command. The RECEIVE

 

 

DIAGNOSTIC RESULTS command cannot read out the error

 

 

information detected in the self-diagnostics.

 

 

Caution

 

 

1.

To avoid shocks, turn off the power before connecting or

6-5

 

 

disconnecting a cable, connector, or plug.

 

 

2.

To avoid injury, do not touch the mechanical assembly during

 

 

 

disk drive operation.

 

 

3.

Do not use solvents to clean the disk drive.

 

 

Caution

 

 

1.

Always ground yourself with a wrist strap connected to ground

6-6

 

 

before handling. ESD (Electrostatics Discharge) may cause

 

 

 

the damage to the device.

 

 

2.

To prevent electrical damage to the disk drive, turn the power

 

 

 

off before connecting or disconnecting a cable, connector, or

 

 

 

plug.

 

 

3.

Do not remove a PCA. This operation is required to prevent

 

 

 

unexpected or unpredictable operation.

 

 

4.

Do not use a conductive cleaner to clean a disk drive assembly.

 

 

5.

Ribbon cables are marked with a colored line. Connect the

 

 

 

ribbon cable to a cable connector with the colored wire

 

 

 

connected to pin 1.

 

 

Damage

 

 

Never open the disk enclosure in the field. Opening the disk

6-6

 

enclosure may cause an irreparable fault.

 

 

Data loss

 

 

Save data stored on the disk drive before requesting repair. Fujitsu

6-7

 

does not assume responsibility if data is destroyed during servicing

 

 

or repair.

 

 

 

 

 