Manuals
/
Fujitsu
/
Computer Equipment
/
Computer Drive
Fujitsu
MAW3073fc, MAW3300FC, MAW3147FC manual Revision Record, Specification No. C141-E235-**EN
Models:
MAW3073fc
MAW3147FC
MAW3300FC
1
5
112
112
Download
112 pages
6.34 Kb
1
2
3
4
5
6
7
8
<
>
Troubleshooting
Specifications
Install
3 Test flowchart
Dimension
Maintenance
Standard Features 1.2 Hardware Structure 1.3 System Configuration
Diagnostics
7 Alternate block allocation by FORMAT UNIT command
Mounting Drives 5.3.1 Mounting procedures
Page 5
Image 5
REVISION RECORD
Edition
Date published
Revised contents
01
June, 2005
Specification No.:
C141-E235-**EN
C141-E235
Page 4
Page 6
Page 5
Image 5
Page 4
Page 6
Contents
C141-E235-01EN
PRODUCT/MAINTENANCE MANUAL
MAW3300FC MAW3147FC MAW3073FC HARD DISK DRIVES
IMPORTANT NOTE TO USERS
FOR SAFE OPERATION
Handling of This Manual
The contents of this manual may be revised without prior notice
This page is intentionally left blank
REVISION RECORD
Specification No. C141-E235-**EN
C141-E235
Related Standards
Chapter 2 Specifications
Preface
Chapter 4 Installation Requirements
Chapter 5 Installation
Preface
APPENDIX A Connector Signal Allocation
CONVENTIONS USED IN THIS MANUAL
Conventions for Alert Messages
Please forward any comments you may have regarding this manual
Preface
C141-E235
This page is intentionally left blank
Important Alert Messages
Important Alert Items
C141-E235
Important Alert Items
C141-E235
Important Alert Items
This page is intentionally left blank
C141-E235
This page is intentionally left blank
CONTENTS
Contents
Contents
Illustrations Figures
Contents
Tables
Contents
This page is intentionally left blank
1.1 Standard Features 1.2 Hardware Structure 1.3 System Configuration
CHAPTER 1 General Description
General Description
1.1 Standard Features
1.1 Standard Features
General Description
12 Error recovery
Figure 1.1 FC model drives outer view
1.2 Hardware Structure
1.2 Hardware Structure
2 Heads
General Description
Figure 1.2 Example of FC-AL system configuration
1.3 System Configuration
1.3 System Configuration
This page is intentionally left blank
2.1 Hardware Specifications
CHAPTER 2 Specifications
2.1 Hardware Specifications 2.1.1 Model name and order number
Table 2.1 Model names and order numbers
Function specifications
Specifications
2.1.2 Function specifications
2.1 Hardware Specifications
2.1.3 Environmental specifications
Specifications
Environmental/power requirements
C141-E235
2.1.5 Reliability
2.1 Hardware Specifications
2.1.4 Error rate
The MTBF is defined as Operating time hours at all field sites MTBF =
Specifications
C141-E235
2.1 Hardware Specifications
4 Data security at power failure
This page is intentionally left blank
3.1.1 Cylinder configuration
CHAPTER 3 Data Format
3.1 Data Space 3.2 Logical Data Block Addressing
3.3 Defect Management
Data Format
Figure 3.1 Cylinder configuration
3.1 Data Space
C141-E235
Data Format
3.1.2 Alternate spare area
Figure 3.2 Spare area in cell
Figure 3.4 Track format
3.1 Data Space
3.1.3 Track format
Figure 3.5 Track skew/head skew
Data Format
3.1.4 Sector format
Figure 3.6 Sector format
Each sector on the track consists of the following fields
3.1 Data Space
C141-E235
Data Format
3.1.5 Format capacity
Format capacity
3.2 Logical Data Block Addressing
3.3.2 Alternate block allocation
Data Format
3.3 Defect Management 3.3.1 Defect list
3.3 Defect Management
Figure 3.7 Alternate block allocation by FORMAT UNIT command
Data Format
Figure 3.8 Alternate block allocation by REASSIGN BLOCKS command
3 Automatic alternate block allocation
3.3 Defect Management
Data Format
Type 2 Reassignment of write fail sector 1 Commands to be applied
4.1 Mounting Requirements 4.2 Power Supply Requirements
CHAPTER 4 Installation Requirements
4.1 Mounting Requirements 4.1.1 External dimensions
4.3 Connection Requirements
Figure 4.1 Dimensions
Installation Requirements
Figure 4.2 HDD orientations 4.1.3 Notes on mounting
4.1 Mounting Requirements
4.1.2 Mounting orientations
Figure 4.3 Mounting frame structure
Installation Requirements
Figure 4.4 Limitation of side-mounting
4.1 Mounting Requirements
Table 4.1 Surface temperature check point
Installation Requirements
Figure 4.5 Surface temperature measurement points
C141-E235
4.1 Mounting Requirements
Figure 4.6 Service clearance area
4.2 Power Supply Requirements
Installation Requirements
MAW3300FC
MAW3147FC
Figure 4.9 Connector location
4.3.1 Connector
4.3 Connection Requirements
Figure 4.8 AC noise filter recommended 4.3 Connection Requirements
Figure 4.10 SCA2 type connector
Installation Requirements
4.3.2 Interface connector
5.1 Notes on Handling Drives 5.2 Setting 5.3 Mounting Drives
CHAPTER 5 Installation
5.5 Dismounting Drives 5.6 Spare Disk Drive
5.1 Notes on Handling Drives
Installation
5.2 Setting 5.2.1 Loop ID setting
5.2 Setting
5.2.2 Mode settings
Motor start mode
5.3 Mounting Drives 5.3.1 Mounting procedures
Installation
5.4.1 Checking initial operation
C141-E235
5.4.2 Checking connection
Installation
Figure 5.1 Checking the HDD connection A
Motor starts when power is turned on d
Figure 5.2 Checking the HDD connection B
Installation
Motor starts by START/STOP command Executing time about 60 seconds
5.4.3 Formatting
C141-E235
2 FORMAT UNIT command
Installation
5.4.4 Setting parameters
C141-E235
Installation
5-12
5-13
C141-E235
5-14
Installation
C141-E235
absolute value
5-15
C141-E235
sequence of
process
5.6 Spare Disk Drive
Installation
5.5 Dismounting Drives
6.1 Diagnostics 6.2 Maintenance Information 6.3 Operation Check
CHAPTER 6 Diagnostics and Maintenance
6.4 Troubleshooting Procedures
6.1 Diagnostics 6.1.1 Self-diagnostics
Diagnostics and Maintenance
Operation of self-diagnostics
6.1 Diagnostics
6.1.2 Test programs
Diagnostics and Maintenance
6.2 Maintenance Information 6.2.1 Precautions
6.2 Maintenance Information
6.2.2 Maintenance requirements
Diagnostics and Maintenance
6.2.3 Maintenance levels
6.2 Maintenance Information
Figure 6.1 Revision label example
Diagnostics and Maintenance
6.2.4 Revision numbers
Figure 6.2 Indicating revision numbers
6.2 Maintenance Information
6.2.5 Tools and test equipment
6.2.6 Tests
Figure 6.3 Test flowchart
Diagnostics and Maintenance
6-10
C141-E235
6.3 Operation Check
6.3.3 Diagnostic test
6.3 Operation Check 6.3.1 Initial seek operation check
6.3.2 Operation test
6.4 Troubleshooting Procedures
Diagnostics and Maintenance
6.4.1 Outline of troubleshooting procedures
This section explains the troubleshooting procedures for disk drive errors
System-level field troubleshooting
6.4 Troubleshooting Procedures
6.4.3 Troubleshooting at the repair site
Diagnostics and Maintenance
Disk drive troubleshooting
Damage 1. Never remove any labels from the drive
6.4.5 Finding possibly faulty parts
6.4 Troubleshooting Procedures
6.4.4 Troubleshooting with parts replacement in the factory
This page is intentionally left blank
7.1 Error Analysis Information Collection 7.1.1 Sense data
CHAPTER 7 Error Analysis
7.1 Error Analysis Information Collection 7.2 Sense Data Analysis
Figure 7.1 Format of extended sense data
Error Analysis
7.2 Sense Data Analysis
7.2.1 Error information indicated with sense data
7.2 Sense Data Analysis
Definition of sense data
7.2.3 Sense data 1-1x-xx, 3-1x-xx and E-1D-00 Disk read error
Error Analysis
C141-E235
7.2.2 Sense data 3-0C-03, 4-40-xx, and 4-C4-xx
A.1 Interface FC-SCA Connector Signal Allocation
APPENDIX A Connector Signal Allocation
Table A.1 FC-SCA connector CN1
Connector Signal Allocation
A.1 Interface FC-SCA Connector Signal Allocation
Command
Glossary
Additonal Sense Code
Device
Target TARG
Glossary
Acronyms and Abbreviations
Acronyms and Abbreviations
Index
IN-2
Index
Index
This page is intentionally left blank
Comment Form
This page is intentionally left blank