(1)Error recovery parameter

The following parameters are used to control operations such as the HDD internal error recovery:

a. Read/write error recovery parameters (page code = 1)

 

Parameter

• AWRE:

Automatic alternate block allocation at Write

 

operation

• ARRE:

Automatic alternate block allocation at read

 

operation

• TB:

Uncorrectable data transfer to the initiator

• EER:

Immediate correction of correctable error

• PER:

Report of recovered error

• DCR:

Suppression of ECC error correction

Retry count at read operation

Retry count at write operation

Recovery time limit

b. Verify error recovery parameters (page code = 7)

 

Parameter

• ERR:

Immediate correction of recoverable error

• PER:

Report of recovered error

• DTE:

Stop of command processing at successful

 

error recovery

• DCR:

Suppression of ECC error correction

Retry count at verification

c. Additional error recovery parameters (page code = 21)

Parameter

• Retry count at seek error

Default value

1(enabled)

1(enabled)

1(enabled)

1(enabled)

0 (disabled)

0 (Correction is

enabled.)

63

63

30 sec

Default value

1(enabled)

0 (disabled)

0 (Processing is

continued.)

0 (Correction is

enabled.)

63

Default value

15