Error Analysis

Error Analysis

Basic information

Additional information

 

Bit

7

6

5

4

 

3

2

1

0

 

 

 

 

 

 

 

 

 

Byte 0

Valid

 

 

X‘70’ or X‘71’ (error code)

 

 

 

 

 

 

 

 

 

 

 

 

1

 

 

 

 

 

X‘00’

 

 

 

 

 

 

 

 

 

 

 

 

 

2

0

 

0

ILI

0

 

 

Sense key

 

 

 

 

 

 

 

 

 

 

 

 

3[MSB]

 

Information

 

5

 

 

 

 

 

 

6

 

[LSB]

 

 

7

X‘28’ (additional sense data length)

8[MSB]

10

 

 

Command-specific information

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

11

 

 

 

 

 

 

 

 

 

[LSB]

 

 

 

 

 

 

 

 

 

 

12

 

 

 

Additional sense code

 

 

 

 

 

 

 

 

 

 

 

13

 

 

Additional sense code qualifier

 

 

 

 

 

 

 

 

 

 

 

 

 

14

 

 

 

 

X‘00’

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

15

SKSV

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

16

 

 

Sense key-specific information

 

 

 

 

 

 

 

 

 

 

 

 

 

17

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

18

0

0

0

 

Port

 

0

 

Link Rate

 

 

 

 

 

 

 

 

 

 

19

 

 

 

CDB operation code

 

 

 

 

 

 

 

 

 

 

 

 

 

20

 

 

 

 

 

 

 

 

 

 

Detail information

47

Figure 7.1 Format of extended sense data