4.3 Connection Requirements

4.3 Connection Requirements

(5)Noise filter

To eliminate AC line noise, a noise filter should be installed at the AC input terminal on the HDD power supply unit. The specification of this noise filter is as follows:

Attenuation: 40 dB or more at 10 MHz

Circuit construction: T-configuration as shown in Figure 4.8 is recommended.

Figure 4.8 AC noise filter (recommended)

4.3Connection Requirements

4.3.1Connector

Figure 4.9 shows the location of interface connector.

Interface connector (CN1) (including power supply)

Figure 4.9 Connector location

C141-E235

4-9

Page 61
Image 61