Diagnostics and Maintenance

When an error is detected in the self-diagnostics, the HDD terminates the SEND DIAGNOSTIC command with the CHECK CONDITION status.

The initiator should issue the REQUEST SENSE command when the CHECK CONDITION status is posted. The sense data collected by the REQUEST SENSE command indicates the detail information of the error detected in the self-diagnostics.

The HDD status after the CHECK CONDITION status is posted differs according to the type of the detected error.

a)When an error is detected in the seek or write/read test, the subsequent command can be accepted correctly. When the command other than the REQUEST SENSE and NO OPERATION is issued from the same initiator, the error information (sense data) is cleared.

b)When an error is detected in the hardware function test, the HDD posts the CHECK CONDITION status for all I/O operation request except the REQUEST SENSE command. The error status is not cleared even if the error information (sense data) is read. Only when the power is turned off or re-turned on, the status can be cleared. When this status is cleared, the HDD executes the initial self-diagnostics again (see item (1)).

Refer to Subsection 4.4.1 “SEND DIAGNOSTIC (1D)” of the Fibre Channel Interface Specifications for further details of the command specifications.

Data loss

When the SEND DIAGNOSTIC command terminates with the CHECK CONDITION status, the initiator must collect the error information using the REQUEST SENSE command. The RECEIVE DIAGNOSTIC RESULTS command cannot read out the error information detected in the self-diagnostics.

6.1.2Test programs

The basic operations of the HDD itself can be checked with the self-diagnostic function. However, to check general operations such as the host system and interface operations in a status similar to the normal operation status, a test program that runs on the host system must be used.

The structure and functions of the test program depend on the user system requirements. Generally, it is recommended to provide a general input/output test program that includes devices connected to the loop and input/output devices on other I/O ports.

Including the following test items in the test program is recommended to test the HDD functions generally.

6-4

C141-E235

Page 82
Image 82
Fujitsu MAW3147FC, MAW3300FC, MAW3073fc manual Test programs

MAW3073fc, MAW3147FC, MAW3300FC specifications

The Fujitsu MAW3073fc, MAW3300FC, and MAW3147FC are high-performance Fibre Channel hard disk drives that cater to enterprise storage solutions. Designed for demanding applications, these drives are engineered to deliver reliability, speed, and capacity, making them suitable for data centers and other high-availability environments.

The MAW3073fc offers a storage capacity of 73GB and operates at 15,000 RPM, ensuring rapid data access and high throughput. This drive features advanced error correction capabilities, enhancing data integrity while minimizing downtime. The MAW3073fc supports the Fibre Channel interface, enabling fast data transfer rates that are essential for high-performance computing scenarios.

Following this, the MAW3300FC steps up the game with a larger capacity of 300GB, also spinning at 15,000 RPM. It boasts enhanced reliability features, including improved thermal management and vibration tolerance, which significantly reduce wear and tear and prolong the drives' lifespan. Its hot-swappable design allows for easy maintenance, making it an ideal choice for critical applications that require minimal disruptions.

The MAW3147FC further expands the offering with a storage capacity of 147GB. Designed for applications that require a balance between performance and capacity, this drive provides a reliable solution for enterprise environments. Like its counterparts, it operates at 15,000 RPM, ensuring swift data retrieval and consistency under heavy loads. The MAW3147FC also implements sophisticated caching algorithms that optimize read and write performance.

All three drives utilize SCSI command sets and feature RAID support, making them compatible with various enterprise storage systems. These drives are built with enterprise-grade components, ensuring durability and reliability, crucial in mission-critical setups. The combination of high RPM speeds, reliability features, and large capacities makes the Fujitsu MAW series an excellent choice for organizations looking to enhance their storage infrastructure.

In terms of technologies, these drives use advanced servo technology and tight mechanical tolerances to achieve high precision and performance. Moreover, they are designed to operate in environments with rigorous temperature and humidity controls, further enhancing their reliability. The MAW series exemplifies Fujitsu's commitment to providing high-quality, performance-driven storage solutions for modern enterprise needs.