Table 1.3 Current and power dissipation
Mode of Operation |
| Typical RMS current (*1) [mA] |
|
| Typical Power (*2) [watts] |
| ||||
|
|
|
|
|
|
| ||||
| +12 V |
| +5 V |
|
| |||||
|
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
| |
Model | MPE3064 | MPE3102/ | MPE3170/ | MPE3273 | All Models | MPE3064 | MPE3102/ | MPE3170/ | MPE3273 | |
| AT | MPE3136 | MPE3204 | AT |
| AT | MPE3136 | MPE3204 | AT | |
|
| AT | AT |
|
|
| AT | AT |
| |
|
|
|
|
|
|
|
|
|
| |
Spin up | 1500 | 1500 | 1600 | 1600 | 572 | 21.1 | 21.1 | 22.3 | 22.3 | |
| 1800 peak | 1800 peak | 1800 peak | 1800 peak | 592 peak |
|
|
|
| |
|
|
|
|
|
|
|
|
|
| |
Idle (Ready) (*3) | 140 | 170 | 200 | 240 | 340 | 3.4 | 3.7 | 4.1 | 4.6 | |
|
|
|
|
|
|
|
|
|
| |
R/W (On Track) (*4) | 180 | 210 | 240 | 280 | 620 | 5.3 | 5.6 | 6.0 | 6.5 | |
|
|
|
|
|
|
|
|
|
| |
Seek (Random) (*5) | 300 | 330 | 360 | 400 | 620 | 6.7 | 7.1 | 7.4 | 7.9 | |
Seek/W/R | ||||||||||
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
| |
Standby | 7 | 7 | 7 | 7 | 185 | 1.0 | 1.0 | 1.0 | 1.0 | |
|
|
|
|
|
|
|
|
|
| |
Sleep | 7 | 7 | 7 | 7 | 185 | 1.0 | 1.0 | 1.0 | 1.0 | |
|
|
|
|
|
|
|
|
|
|
*1 Current is typical rms except for spin up.
*2 Power requirements reflect nominal values for +12V and +5V power.
*3 Idle mode is in effect when the drive is not reading, writing, seeking, or executing any commands. A portion of the R/W circuitry is powered down, the spindle motor is up to speed and the Drive ready condition exists.
*4 R/W mode is defined as 50% read operations and 50% write operations on a single physical track.
*5 Seek/W/R mode is defined as 33% seek operations, 33% write operations and 33% read operations.
1 - 6 |