Fujitsu MPE3XXXAT manual Current and power dissipation

Models: MPE3XXXAT

1 191
Download 191 pages 28.71 Kb
Page 21
Image 21

Table 1.3 Current and power dissipation

Mode of Operation

 

Typical RMS current (*1) [mA]

 

 

Typical Power (*2) [watts]

 

 

 

 

 

 

 

 

 

+12 V

 

+5 V

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Model

MPE3064

MPE3102/

MPE3170/

MPE3273

All Models

MPE3064

MPE3102/

MPE3170/

MPE3273

 

AT

MPE3136

MPE3204

AT

 

AT

MPE3136

MPE3204

AT

 

 

AT

AT

 

 

 

AT

AT

 

 

 

 

 

 

 

 

 

 

 

Spin up

1500

1500

1600

1600

572

21.1

21.1

22.3

22.3

 

1800 peak

1800 peak

1800 peak

1800 peak

592 peak

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Idle (Ready) (*3)

140

170

200

240

340

3.4

3.7

4.1

4.6

 

 

 

 

 

 

 

 

 

 

R/W (On Track) (*4)

180

210

240

280

620

5.3

5.6

6.0

6.5

 

 

 

 

 

 

 

 

 

 

Seek (Random) (*5)

300

330

360

400

620

6.7

7.1

7.4

7.9

Seek/W/R

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Standby

7

7

7

7

185

1.0

1.0

1.0

1.0

 

 

 

 

 

 

 

 

 

 

Sleep

7

7

7

7

185

1.0

1.0

1.0

1.0

 

 

 

 

 

 

 

 

 

 

*1 Current is typical rms except for spin up.

*2 Power requirements reflect nominal values for +12V and +5V power.

*3 Idle mode is in effect when the drive is not reading, writing, seeking, or executing any commands. A portion of the R/W circuitry is powered down, the spindle motor is up to speed and the Drive ready condition exists.

*4 R/W mode is defined as 50% read operations and 50% write operations on a single physical track.

*5 Seek/W/R mode is defined as 33% seek operations, 33% write operations and 33% read operations.

1 - 6