Appendix A Operation Checksheet (Installation/Operation Check) 87
E
Others
9When this
product (the
server if it is
built in the
server) is turned
off or restarted,
is the data
cartridge
ejected?
This product writes the data cartridge
management data when the data cartridge is
ejected. Therefore, if the power of the server is
turned off while the data cartridge is inside this
product, a faulty tape where no management data
can be written will be created and problems such
as data restore failure will occur.
* Before turning off the server, eject the data
cartridge.
* To execute backup automatically for schedul-
ing etc, follow the procedure in "1.5 Setting
Backup Job (Setting Automatic Ejection)"
(Jpg.66) to output automatically.
10 Are two or more
data cartridges
used for backup
and generation
management?
(Is the different
data cartridge
used for every
time?)
When using a single data cartridge repeatedly for
backup, important backup data may be lost if the
backup fails or the backedup data cartridge is
damaged.
* Use two or more data cartridges for backup and
perform generation management.
Classification No Check Check item Description / tasks (*)