Indicator LEDs

There are three main indicator LEDs on the front of the XG1200: Power LED, Alarm LED, and Status LED. The following explains the LED display under various conditions.

 

XG1200 Condition

 

LED

 

 

 

 

 

 

Power

Alarm

Status

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Off

 

 

Off

Off

Off

 

 

 

 

 

 

Starting up

 

Power just turned on

On

On

Off

 

 

 

 

 

 

 

 

System starting up

On

Off *1

Blinking

 

 

 

 

 

 

 

 

System start-up completed

On

Off *1

On

 

 

 

 

 

 

Operable

 

 

On

Off *1

On

 

 

 

 

 

 

After shutdown

 

 

On

Off*1

Off

 

 

 

 

 

 

*1: If the XG1200 is operating normally.

If a problem occurs, the front panel LEDs and the LEDs on the individual parts can be used to identify the trouble:

 

XG1200 Condition

 

 

LED

 

 

 

 

 

 

 

 

Power

Alarm

Status

 

LED on failed part

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Startup error

On

Blinking

Blinking

 

---

 

 

 

 

 

 

 

 

 

 

Front fan error

On

On

--- *3

 

Front Fan LED: On

 

 

 

 

 

 

 

 

 

 

Rear fan error

On

On

--- *3

 

Rear Fan LED: On

detected

 

 

 

 

 

 

 

 

Power fan error

On

On

--- *3

 

Power Fail LED: On

 

 

 

 

 

 

 

 

No AC supply *2

On

On

--- *3

 

Power Fail LED: On

 

 

 

 

 

 

 

 

Power supply error

On

On

--- *3

 

Power Fail LED: On

Problem

 

 

 

 

 

 

 

 

 

 

Voltage error

On

On

--- *3

 

---

 

 

 

 

 

 

 

 

Temperature error

On

On

--- *3

 

---

 

 

 

 

 

 

 

 

 

 

Xenpak error

On

On

--- *3

 

---

 

 

 

 

 

 

 

 

 

 

System dump in

On

On

--- *3

 

---

 

 

progress

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

*2: Only detectable and indicated when two power supply units are installed and connected to separate, independent power supplies.

*3: Condition of the Status LED will depend on the state of the system.

Note that the XG1200 does not shut itself off when trouble is detected.

Any problems other than those that occur during start up are recorded in the event log. For details of the event log, refer to the "User Guide".