Fujitsu XG1200 manual Set up requirements, Temperature 5 - 40C Humidity 20 - 80%RH

Models: XG1200

1 40
Download 40 pages 15.54 Kb
Page 25
Image 25
Set up requirements

Set up requirements

Only use the XG1200 under the temperature, humidity and other environmental conditions specified in "A.2 Installation Specifications" (page 38). Using the XG1200 outside the follow- ing ranges can shorten the lifetime or cause the failure of the XG1200.

-Temperature (5 - 40°C)

-Humidity (20 - 80%RH)

When installing the XG1200 in a rack, note the following.

Certain types of racks cannot be used. To check whether the XG1200 can be installed in a given rack, contact the vendor's service department.

-Temperature (5 - 40°C)CAUTION

Remember that when an installed unit is operating, the temperature inside the rack will be higher than the external ambient temperature, particularly if the rack con- tains multiple units. The rack’s internal ambient temperature should not be allowed to exceed the maximum ambient temperature specified for each installed unit. The maximum ambient temperature allowed for the XG1200 is 40°C.

A certain amount of air is required for the XG1200 to operate safely. Make sure that adequate ventilation is provided and that the front and rear air vents are not obstructed.

Be careful that the rack is able to supply sufficient power for all the installed units. To avoid overloading the rack, check the power requirements specified for the each installed unit. The power requirement of the XG1200 are 0.23kVA.

Installing the XG1200 in a rack may cause the entire rack to become unstable. To avoid this, fix the rack to the wall or floor as appropriate.

Check that all the installed units are correctly grounded. Special care should be taken if the unit's power supply is not drawn directly from the distribution board (such as when a power strip is used, for example). When multiple devices are con- nected to a single power strip, the combined leakage currents can overwhelm the grounding capacity of the power strip.

24

Installation and Operation

Page 25
Image 25
Fujitsu XG1200 manual Set up requirements, Temperature 5 - 40C Humidity 20 - 80%RH, Installation and Operation