Color monitor 4612 FA
Environmental conditions |
|
Environment class 3K2, IEC 721 |
|
Rated range of operation: | 15 °C .... 35 °C |
Humidity: | 20 % .... 85 % |
Limit range of operation: | 5 °C .... 35 °C |
Humidity: | 20 % .... 85 % |
Condensation must be avoided. |
|
VESA-DDC-compatible VGA interface
Your monitor is equipped with a
i | If the monitor 4612 FA is not yet displayed in the list of monitors, you can select the |
following monitor instead: | |
| Siemens MCF 4611 TA |
Preset operating modes
The display position and size have been set to optimum values at the factory for the i operating modes listed above. Depending on the screen controller used, it may be
necessary to adjust the display position and size. In this case, you can change and save the settings (see "Operation of the monitor").
The following are the most frequently used of the preset operating modes:
Horizontal frequency | Refresh rate | Screen resolution |
|
|
|
31,5 kHz | 70 Hz | 720 x 400 |
31,5 kHz | 60 Hz | 640 x 480 |
37,5 kHz | 75 Hz | 640 x 480 |
37,9 kHz | 60 Hz | 800 x 600 |
46,9 kHz | 75 Hz | 800 x 600 |
48,4 kHz | 60 Hz | 1024 x 768 |
60,0 kHz | 75 Hz | 1024 x 768 |
64,0 kHz | 60 Hz | 1280 x 1024 |
80,0 kHz | 75 Hz | 1280 x 1024 |
|
|
|
For ergonomic reasons, a screen resolution of 1024 x 1280 pixels is recommended. Because of the technology used (active matrix) an LCD monitor provides a totally
20 - English |