10 Installation

10.1Installation Steps

VCAUTION!

The storage subsystem should not be subjected to any extreme environ- mental conditions (see section “Technical Data” on page 4). Protect it from dust, moisture and heat.

The storage subsystem must be acclimatized in its operating environment for an acclimatization time.

Temperature difference (°C)

Minimum acclimatization time

(operating environment/outside)

(hours)

 

 

5

3

 

 

10

5

 

 

15

7

 

 

20

8

 

 

25

9

 

 

30

10

 

 

Table 14: Acclimatization Time

The following installation steps are described in detail in other sections of this chapter:

Unpacking the storage subsystem.

Setting up the floorstand model or mounting the rack model into the rack.

Cabling the storage subsystem (see chapter “Connections” on page 57).

Setting the desired system parameters.

Connecting the storage subsystem to the mains voltage (see section “Mains Connection” on page 58 or section “Mains Connection with Phase Redun- dancy” on page 59).

Switching ON the storage subsystem.