Power Supply Units

Power Supply

5.1.1Replacing the Power Supply Unit

VCAUTION!

It is imperative that you read the chapter “Important Notes” on page 7 in this manual before you carry out work on your storage subsystem.

If faults occur with the power supply, it could be necessary to replace a power supply unit. Information about the relevant error messages can be found in the sections “Meaning of the S60 Operating Status LEDs” on page 16, “Power Supply Unit LEDs” on page 21 and in the chapter “Troubleshooting” on page 71.

Figure 11: Power Supply Unit Removed

VCAUTION!

When a power supply unit is replaced in a non-redundant power supply system (only one power supply unit present) the server must be switched OFF and/or the FC channels deactivated.

ÊIf only one power supply unit is present, shut down the server and switch it OFF.

ÊRemove the cable of the defective power supply unit.

ÊRaise the lower catch on the power supply unit and carefully remove it from its slot by pulling on the upper catch. To remove the power supply unit the lower catch must be in the up position.