Furuno 1823C, 1933C, 1943C, 1833C, GD-1900C NETWORK port, Connecting GP-310B/320B to DATA 2 port

Models: 1943C

1 100
Download 100 pages 8.64 Kb
Page 39
Image 39
Connecting GP-310B/320B to DATA 2 port

Connecting GP-310B/320B to DATA 2 port

When an equipment is connected to DATA 1 port, GPS receiver GP-310B/320B can be connected to DATA 2 port as shown below.

You need a junction box and optional cable MJ-A6SPF0003-050 or MJ-A6SPF0009-100.

DISPLAY UNIT

 

 

 

 

MJ-A6SPF0003-050

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MJ-A6SPF0009-100

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

GP-310B/320B

DATA 2

 

 

 

 

 

 

 

 

 

 

 

JUNCTION BOX

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TD-A

1

 

 

 

 

 

BLK

 

 

1

 

 

 

WHT

 

 

 

RD-A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BLU

 

 

 

 

 

 

 

 

WHT

 

 

 

 

 

 

TD-B

2

 

 

 

 

 

 

 

 

 

 

 

 

2

 

 

 

 

 

 

RD-B

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

YEL

 

 

 

 

 

 

 

 

GRN

 

 

 

 

 

 

 

RD-A

3

 

 

 

 

 

 

 

 

 

 

 

3

 

 

 

 

 

 

TD-A

 

 

 

 

 

YEL

 

 

 

 

 

GRN

 

 

 

RD-B

4

 

 

 

 

 

 

 

 

 

 

 

4

 

 

 

 

 

 

TD-B

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RED

 

 

 

NC

5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5

 

 

 

 

 

+ 12V

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BLK

 

 

SHIELD

6

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

6

 

 

 

 

 

GND

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

7

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Power

Power supply

DC/DC CNV

supply

Type: Insulation

 

 

Connecting GP-310B/320B to DATA 2 port

NETWORK port

Other NavNet equipment should be connected to this port with the optional MJ-A6SPF0014 cable. Available equipments are shown below.

Radar

Plotter

Network sounder

Other

 

 

 

 

MODEL1722/1732/

 

 

 

1742/1762/1722C/

 

ETR-6/10N

HUB (used when more

1732C/1742C/1762C/

GD-1700/1700C/1900C

than two NavNet units

1752C/1823C/1833/

ETR-30N

 

are connected.)

1933/1943/1833C/

 

 

 

 

 

1933C/1943C/1953C

 

 

 

 

 

 

 

2-3