2.3.3 Start and stop of recording

within 2000.024999.9kHz).

..3 Start and stop of recording

(1) Start

Recording starts automatically (Start/Stop, Phase, Speed, IOC) by receiving the APSS signal. To start halfway of the received picture, press RCD key once and automatic speed setting and auto-phasing mode are set. Then, recording starts upon phasing is completed. When the phase signal for automatic start is not received, recording does not start. Then, press RCD key again for manual recording.

(2) Stop

Recording stops automatically when auto stop signal is received. In the absence of auto stop signal or to stop halfway, press RCD key.

..Manual phasing

In manual recording mode or when the phasing is not completed in the proper position by auto phasing,

be sure to adjust the phase using the 2.3.4 Manual phasing key.

The phase signal shifts by 2.5% of the paper width or about 6.4mm per keying.

..Synchronization

When a recorded picture (phase signal, etc.) drifts to left or right, be sure to adjust the synchronization with SYNC knob to stop drift.

SYNC

Turn counter-

Turn

clockwiseclockwise

When the picture is such as shown in the left illustration ( ), turn the knob counter-clockwise. In case of the right illustration (), turn the knob clockwise.