6.3 Activating the Auto Plotter
To activate the
1.Adjust the GAIN, A/C SEA and A/C RAIN controls for proper radar picture.
2.Press the [MENU] key to open the main menu.
3.Operate the trackball to select
4.Press the [ACQ/ENTER] key. The menu shown in Figure
[ ARP MENU ] Select item by
1 . Display | Off |
| On |
| |||||
2 | . All Cancel |
|
|
|
|
|
| ||
3 | . Vector Ref | Rel |
| True |
| ||||
4 | . Vector Length |
|
|
|
| 30sec | 1min | ||
|
|
|
| 3min | 6min | 15min |
| ||
|
|
|
| 30min | |||||
5 | . History |
| Off |
| 15sec | 30sec | 1min | ||
|
|
|
| 2min | 3min | 6min |
| ||
6 | . CPA Set |
|
|
| 0.5nm | 1nm | 2nm | ||
| Off | ||||||||
|
|
|
| 3nm | 5nm | 6nm |
| ||
7 | . TCPA Set |
|
|
| 1min | 2min | 3min | ||
30sec | |||||||||
|
|
|
| 4min | 5min | 6min | 12min | ||
8 | . Auto ACQ |
|
|
|
|
| On |
| |
| Off |
|
|
5. | Operate the trackball to select the menu item | Figure |
| “1. Display”. |
|
6. | Operate the trackball to select “On”. |
|
7. | Press the [ACQ/ENTER] key. |
|
8. | Press the [MENU] key to close the menu. |
|
Target is being tracked but is not selected for data readout
| 8 NM |
Target Full | 2 AUTO TARGET |
SP FULL | |
Mark | HU RM |
|
Lost Target
HDG 234.5°
TRAIL AUTO
25:38 30min
G (OUT)
ZOOM
ES1
Threatening target
Target selected for data reading (large square)
Auto
Acquisition
Area
A/C |
|
|
|
|
AUTO |
|
|
| VRM |
EBL/PI |
|
|
| |
345.6°R | 13.5°R | 0.142NM | 0.048NM | |
23.0°R |
|
| 0.100NM | |
| BEARING 42.5°T | COURSE 287.8°T | ||
TRUE VECTOR | RANGE | 5.36 NM | SPEED | 12.5 KT |
15 MIN | CPA | 2 NM | TCPA | 12:35 |
ARPA Data Area