6.3 Activating the Auto Plotter

To activate the ARP-10, follow the steps shown below.

1.Adjust the GAIN, A/C SEA and A/C RAIN controls for proper radar picture.

2.Press the [MENU] key to open the main menu.

3.Operate the trackball to select “ARP-10 MENU”.

4.Press the [ACQ/ENTER] key. The menu shown in Figure 6-1 appears.

[ ARP MENU ] Select item by T-ball and press ENTER key.

1 . Display

Off

 

On

 

2

. All Cancel

 

 

 

 

 

 

3

. Vector Ref

Rel

 

True

 

4

. Vector Length

 

 

 

 

30sec

1min

 

 

 

 

3min

6min

15min

 

 

 

 

 

30min

5

. History

 

Off

 

15sec

30sec

1min

 

 

 

 

2min

3min

6min

 

6

. CPA Set

 

 

 

0.5nm

1nm

2nm

 

Off

 

 

 

 

3nm

5nm

6nm

 

7

. TCPA Set

 

 

 

1min

2min

3min

30sec

 

 

 

 

4min

5min

6min

12min

8

. Auto ACQ

 

 

 

 

 

On

 

 

Off

 

 

5.

Operate the trackball to select the menu item

Figure 6-1 ARP menu

 

“1. Display”.

 

6.

Operate the trackball to select “On”.

 

7.

Press the [ACQ/ENTER] key.

 

8.

Press the [MENU] key to close the menu.

 

Target is being tracked but is not selected for data readout

 

8 NM

Target Full

2 AUTO TARGET

SP FULL

Mark

HU RM

 

Lost Target

HDG 234.5°

TRAIL AUTO

25:38 30min

G (OUT)

ZOOM

ES1

Threatening target

Target selected for data reading (large square)

Auto

Acquisition

Area

A/C

 

 

 

 

AUTO

 

 

 

VRM

EBL/PI

 

 

 

345.6°R

13.5°R

0.142NM

0.048NM

23.0°R

 

 

0.100NM

 

BEARING 42.5°T

COURSE 287.8°T

TRUE VECTOR

RANGE

5.36 NM

SPEED

12.5 KT

15 MIN

CPA

2 NM

TCPA

12:35

ARPA Data Area

Figure 6-2 ARP display

6-3

Page 41
Image 41
Furuno FR-7062, FR-7252, FR-7112 manual Activating the Auto Plotter, ARP menu