Furuno FR-7062, FR-7252, FR-7112 manual Environmental Condition

Models: FR-7252 FR-7112 FR-7062

1 52
Download 52 pages 3.1 Kb
Page 47
Image 47

 

Heading (Magnetic):

HDM>HDG*1>HDT*1>VHW>VHW*1

 

Course (True):

RMC>RMA>VTG

 

Course (Magnetic):

VTG>RMC>RMA

 

Waypoint(Range, Bearing):

RMB>BWC>BWR

 

Loran time difference:

RMA>GLC>GTD

 

Water depth:

DPT>DBT>DBK>DBS

 

Water temperature:

MTW>MDA

 

Time:

ZDA

 

XTE:

RMB>XTE>APB

 

 

*1: calculate by magnetic drift.

(7)

Output Data

NMEA0183(Ver.1.5/2.0), RS-422

 

 

TLL (target data) and RSD

5. ENVIRONMENTAL CONDITION

(1)

Ambient Temperature

Scanner Unit: -25°C to +70°C

 

 

Display Unit: -15°C to +55°C

(2)

Relative Humidity

95 % or less at +40°C

(3)

Waterproofing

 

 

Scanner Unit

IPX6

 

Display Unit

Chassis: not specified

 

 

Panel: IPX4

6. POWER SUPPLY & POWER CONSUMPTION

(1)

Power Supply

FR-7062/7112: 12/24/32 VDC (10.8 to 41.6 VDC)

 

 

FR-7252: 24/32 VDC (21.6 to 41.6 VDC)

(2)

Voltage and Current

 

 

FR-7062

XN12A(24rpm): 12 VDC/7.8A, 24VDC/3.9A, 32VDC/2.9A(100 kt)

 

 

XN12A(48rpm): 12 VDC/8.8A, 24VDC/4.4A, 32VDC/3.3A(70 kt)

 

 

XN13A(24rpm): 12VDC/10A, 24VDC/5A, 32VDC/3.8A(100 kt)

 

FR-7112

XN12A(24rpm): 12 VDC/8.6A, 24VDC/4.3A, 32VDC/3.2A(100 kt)

 

 

XN12A(48rpm): 12 VDC/10A, 24VDC/5A, 32VDC/3.8A(70 kt)

 

 

XN13A(24rpm): 12 VDC/10.8A, 24VDC/5.4A, 32VDC/4.1A(100 kt)

 

FR-7252

XN12A(24rpm): 24VDC/5.2A, 32VDC/3.9A(100 kt)

 

 

XN12A(48rpm): 24VDC/5.8A, 32VDC/4.4A(70 kt)

 

 

XN13A(24rpm): 24VDC/6.3A, 32VDC/4.7A(100 kt)

(3)

Power Consumption

 

 

FR-7062

XN12A(24rpm): 70 W to 90 W(100 kt)

 

 

XN12A(48rpm): 85 W to 105 W(70 kt)

SP - 3