| SPEED™eS PRO | Maintenance for Your Drive |
|
WARNING: Make absolutely sure that you remove the correct drive as indicated in the steps below.
REMOVING THE WRONG DRIVE CAN RESULT IN THE LOSS OF THE ARRAY AND ALL OF THE CONTENT STORED ON
5.The failed drive’s LED will begin to blink in the
the wrong drive could cause data loss.
NOTE: It is possible the failed drive will be completely | Drive Activity LED |
| |
offline. In this case, the drive’s Activity LED will be com- |
|
pletely turned off, indicating the failed drive. |
|
6.Remove the failed drive by inserting the provided key into the Lock hole and sliding the drive out of the enclosure.
7.Replace the failed drive with a new disk module and secure in place. Once the drive has spun up to speed, the ConfigTool will indicate that the array is rebuilding. The rebuild time is approximately 1 hour per TB.
Once the rebuild is complete,