Aligning the appliance
To ensure that the appliance functions correctly, it must be set level with a spirit level.
If the appliance is not level, water may flow out of the ice maker, ice cubes may be irregular or the doors may not close properly.
Electrical connection
ãWARNING
–Avoid the risk of an electric shock!
–Insert into a grounded
Never remove grounding phase. Do not use any adapters. Do not use any extension cables.
–
The socket must be near the appliance and also freely accessible following installation of the appliance.
The appliance complies with protection class I. Connect the appliance to 115 V/60 Hz alternating current via a correctly installed socket with protective conductor. The socket must be fused with a 10 to 16 A fuse.
The appliance comes with a UL registered
Appliance | Maximum |
| simultaneous |
| load |
|
|
Refrigerator 24" (60.3 cm) | 2.0 amps |
|
|
Refrigerator 30" (75.6 cm) | 2.0 amps |
|
|
Freezer 18" (45.1 cm) * | 3.5 amps |
|
|
Freezer 24" (60.3 cm) * | 4.0 amps |
|
|
Freezer 30" (75.6 cm) * | 4.5 amps |
|
|
Wine storage cabinet 18" (45.1 cm) | 2.0 amps |
|
|
Wine storage cabinet 24" (60.3 cm) | 2.0 amps |
|
|
Check on the rating plate whether the indicated voltage and current type correspond with the values of your power supply. The location of the rating plate can be found in the chapter entitled Customer service.
ãWARNING
Never connect the appliance to electronic energy saver plugs. Our appliances can be used with mains and
Water connection
ãCAUTION
Connect the appliance to a drinking water line.
The water may be connected only by a competent fitter according to the local regulations of the appropriate water supply company.
A cold water connection is necessary for operating the automatic ice maker. The water pressure must be between 25 and 120 p.s.i. (1,72 and 8,25 bar).
The installation must correspond to the local plumbing regulations.
Aseparate
For connection to the drinking water mains use only water pipes which are suitable for drinking water. Observe national regulations and the connection conditions of the local water supply companies.
When installing the water connection, observe the permitted installation areas for the pipe. For the permitted installation areas and dimensions see “Dimensions of the installation niche”.
The maximum outside diameter of the water mains (without connecting pieces) is 3/8" (9.5 mm).
8