Do not use these cleaning agents
▯Caustic or corrosive cleaners
▯Don't allow acidic cleaners (e.g. vinegar, citric acid, etc.) to get on the frame or panel
▯Cleaners containing chlorine or large proportions of alcohol
▯Baking oven spray
▯Hard, scratchy
▯Thoroughly wash out new sponge cloths before using them.
Troubleshooting
You can often easily eliminate problems that may occur on your own. Before calling customer service, take into account the following information.
Malfunction | Possible cause | Solution |
|
|
|
Burner doesn't ignite when | No power supply. | Turn control knob to 0. Check in the fuse box |
turned on; indicator lights are off. |
| whether the fuse has opened. |
Burner doesn't ignite when turned on; indicator light of activated burner blinks.
Burner or gas supply malfunction. Turn control knob to 0.
Check:
▯Burner parts correctly in place?
▯Gas stop tap open?
▯Burner dry and clean?
▯Air pocket in pipeline after first connection or cylinder change (with liquefied gas)?
▯Gas cylinder empty (with liquefied gas)?
Burner turns off during operation, Burner or gas supply malfunction. | Turn all control knobs to 0. Wait until the appliance | |
indicator lights go out and only | has cooled down! | |
the indicator of the burner | With this burner, check: | |
affected continues blinking for a | ||
▯ Burner parts correctly in place? | ||
few seconds. | ||
▯ Electrode dirty (food remains) or damp? | ||
| ||
| ▯ Burner dirtied with spilled food? | |
| ▯ Strong draft of air (e.g. open window directly | |
| behind the gas stovetop)? | |
| ▯ Gas cylinder empty (with liquefied gas)? |
Burners turn off while in | Power failure |
operation, indicator lights go out. |
|
Turn all control knobs to 0. Check power supply. There is no automatic
Burners turn off while in | Overheating protection | Turn all control knobs to 0. Wait until indicator lights |
operation; all indicator lights |
| stop blinking. |
blink. |
|
|
It smells like gas in the kitchen. | Potential leak at gas cylinder |
| connection. |
Check gas cylinder connection for leaks.
14