Installation Of Pump Unit

Pump Unit: The Pump unit will need to be mounted within 20” of the ECU. We reccommend that it be mounted in a horizontal position, preferably floor mounted to a solid surface. Do not install the pump vertically with the pump head down. (Air

!will be trapped in pump head) Do not lengthen or splice the #5 wire or the orange and black power wires. Do not use

Teflon tape on any hydraulic fitting, but for a leak free hydraulic system, we do advise you to use an appropriate thread sealant such as Loctite “Pro Lock” multipurpose anaerobic gel, part number 51604 or equivalent on all pipe threads in the hydraulic system. The Pump connects to #5 at the ECU and the orange and black wires connect to orange and black wire connection at the ECU. Please See page 18

Mounting Template: Use the mounting template you received with your unit. It will allow you to pre-drill the holes you will need to mount the Hydraulic pump unit.

Note: This piston pump may cause the hydraulic lines to vibrate as fluid flows through them. This may cause noise when the autopilot is running. Tying down the hydraulic lines to a solid surface will help eliminate this problem.

To reduce pump noise while the autopilot is running, use of a vibration isolation mounting pad is suggested.

Correct Mounting Position

Wall Mounted

Vertical

Mount

Pump Head Up

Horizontally

15

Page 15
Image 15
Garmin TR-1 manual Pump Head Up Horizontally, Installation Of Pump Unit