Magnum 6K25e Gigabit Fiber Switch

Installation and User Guide (10/07)

For DC internal power supplies at –48VDC, 24VDC and 125VDC, including Dual Source options (for continuity of operation when either of the DC input sources are interrupted), see Appendices B and C.

Per-port MDI or MDIX on RJ-45

The copper daughter board has MDI-MDIX Auto-crossover on all the RJ-45 ports., and eliminate the use of cross-over cable between the devices. Also port- specific user settings (such as FDX or HDX, copper 10/100 speed) can be fixed using software commands.

Alarm Contact (Optional)

Alarm Contact option is offered as a configuration option. The two alarm contacts are SPST NC Form-C relays, and an open condition indicates abnormal status. The Hardware Alarm monitors internal power on the main board, and the Software Alarm is activated by one or more user-selected software traps.

Agency Approvals

UL listed (UL60950), cUL, CE, Emissions meet FCC Part 15 Class A NEBS Level 3 and ETSI Certified for Carrier Central Offices

IEEE 1613 Class 2 Environmental Standard for Electric Power Substations See also Note for Power Substations in Section 3.2.4, 3.6.1, and 5.2.9

IEC 61850 EMC and Operating Conditions Class C for Power Substations

Warranty: Three years, return to factory

Made in USA

NEBS Testing and Certification: NEBS certified

Email sales@GarrettCom.com for details.

www . GarrettCom . com