Magnum 6K32F/FR/FC/FRC Managed Switch Installation and User Guide (05/08)
The various SFPs transceivers supported by GarrettCom 6KQs D slot are-
Module Model# Gigabit
Gb Modules, fixed ports--SFP (Small Form Factor)
6KP2-2GSFP 2 SFP
6KP2-1GSFP1CU 1SFP
31 www Garre ttCom com
..
1 CU
6KP1-1SFP 1SFP
6KP1-1GCU 1 CU
Gb SFP fiber optic transceivers
Gb SX, 850nm wavelength, 500 m distance
SFP-SX
SFP-LX10 Gb LX, 1310nm wavelength, 10km dist
SFP-LX25 Gb LX, 1310nm wavelength, 25km
distance
SFP-ZX40 Gb ZX, 1550nm wavelength, 40km distance
SFP-ZX70
3.2.7 Power Budget Calculations for Magnum 6K32F Series PM’s with Fiber Media Gb ZX, 1550nm wavelength, 70km distance
Receiver Sensitivity and Transmitter Power are the parameters necessary to
compute the power budget. To calculate the power budget of different fiber media
installations using Magnum products, the following equations should be used:
OPB (Optical Power Budget) = PT(min) - PR(min)
where PT = Transmitter Output Power, and PR = Receiver Sensitivity
Worst case OPB = OPB - 1dB(for LED aging) - 1dB(for insertion loss)
Worst case distance = {Worst case OPB, in dB} / [Cable Loss, in dB/Km]
where the “Cable Loss” for 62.5/125 and 50/125μm (M.m) is 2.8 dB/km,
and the “Cable Loss” for 100/140 (Multi-mode) is 3.3 dB/km,
and the “Cable Loss” for 9/125 (Single-mode) is 0.5 dB/km
and the “Cable Loss” for 9/125 (Single-mode) is 0.4 dB/km (LXSC25)