Magnum 6K32F/FR/FC/FRC Managed Switch Installation and User Guide (05/08)
Step 2. Remove retaining screws placed on top for the 6KPM
On the top of the daughter module there are seven retaining screws for each 6KPM card.
These screws are used to secure a 6KPM card in position (see Figure 3.5.3a). Remove the
three standoffs holding the
Granddaughter board with the
chassis.
Figure 3.5.3a: Top View ā€“ 7
retaining screws shown by
arrows
Step 3. Remove 6KPM Card
Carefully and gently pull out the daughter board from the latching connectors, using both
hands, gripping the board near the latch-up connectors as shown in Fig. 3.5.3b . If the
now empty slot is to remain unused, be sure to install a 6KM-BLNK face plate cover.
Figure 3.5.3b: Removing a 6KPM Card
ollow the step 8 to complete the process successfully.
F
NOTE:1. If the modular slot has not being used and moved to other unit, the empty
slot must be covered with Blank cover, to maintain proper air-inflow inside the unit
and keep off from dust and other unavoidable substance, otherwise can cause a failure
onfirm the successful installation, before placing the chassis cover.
in the Switch.
2. If the PM module in the modular slot is not being installed properly or loose in
connection, the MNS-6K management software will not boot-up properly and a error
will generate as ā€“{ failed to read register device type (offset 0x1600) on slot ā€œA or B or
C or Dā€}, whichever the slot has been used.
3. Always boot-up the Switch after any new module installation on modular slot to
c