GarrettCom 6K8 Connecting Ethernet Media, Connecting Fiber Optic ST-type, twist-lock, Copper

Models: 6K8

1 69
Download 69 pages 29.41 Kb
Page 28
Image 28

Magnum 6K8-Series Industrial Field Switch Installation and User Guide 03/06)

For AC power input, locate an AC receptacle that is within six feet (2 meters) of the intended Magnum 6K8-Series site. The rugged metal case of the Magnum 6K8- Series will normally protect it from accidental damage in a lab or workplace setting.

Maintain an open view of the front to visually monitor the status LEDs. Keep an open area around the unit so that cooling can occur from convection while the unit is in operation. The 6K8-Series has no fans, so it is silent when in operation. Internal electronics use the case as a heat sink, so the unit may normally be quite warm to the touch.

3.2Connecting Ethernet Media

The Magnum 6K8-Series Switches are specifically designed to support all standard Ethernet media types within a single Switch unit. This is accomplished by using a family of different port Modules which can be individually selected and configured per-port. See Section 2.4 for a description of the PMs.

The various media types supported along with the corresponding IEEE 802.3, 802.3D, 802.3u, 802.3AB and 802.3z standards and connector types are as follows:

IEEE Standard

Media Type

Max. Distance

Port Module

Fiber:

mm1 Fiber

 

 

1000BASE-FX

220m ( ft)

GBIC-SXSC

 

sgl.m2 Fiber

5,10,25,70Km

GBIC-LXSC

100BASE-FX

mm1 Fiber

2.0km (6,562 ft)

6K6-MSC, -MST

 

sgl.m2 Fiber

18.0km (95K ft)

SSC, SSCL

small form factor

mm1 Fiber

2.0km (6,562 ft)

6K8-MTRJ, -MLC

small form factor

sgl.m1 Fiber

15 km

6KP8V- SLC

Copper:

 

 

 

10BASE-T,100BASE-TX twisted pair

100m (328 ft)

6K8-RJ45

1000BASE-TX

 

 

GBPM-RJ45

1 mm = multi-mode

2 sgl.m = single-mode

 

3.2.1Connecting Fiber Optic ST-type, “twist-lock”

The following procedure applies to installations using a PM with ST-type fiber connectors. This procedure applies to ports using a 6K8-Series module, MST- type port.

1.Before connecting the fiber optic cable, remove the protective dust caps from the tips of the connectors on the PM. Save these dust caps for future use.

2.Wipe clean the ends of the dual connectors with a soft cloth or lint-free lens tissue dampened in alcohol. Make certain the connectors are clean before connecting.

Note: One strand of the duplex fiber optic cable is coded using color bands at regular intervals; you must use the color-coded strand on the associated ports at each end of the fiber optic segment.

www . GarrettCom . com

23

Page 28
Image 28
GarrettCom 6K8 manual Connecting Ethernet Media, Connecting Fiber Optic ST-type, twist-lock, Copper