3.5Alarm Contacts for monitoring internal power, and Software Traps
The Alarm Contacts feature, standard on Magnum
two Form C Normally Closed (NC) contacts to which the user can attach two sets of status monitoring wires at the green terminal block. When this option is present, the terminal block for Alarm Contacts is part of the Power Input panel in the Magnum 6K8- ’s case. The AC or DC power input connection is in the same panel. A manual
The first NC Alarm Contact (top position) is a “Software Alarm”, operated by user settings in the
the Software Alarm is enabled, the Form C Normally Closed (NC) contact is held close during normal software operation. A
The second (bottom position) NC Alarm Contact is held close when there is power on the main board inside of the
contacts will open when internal power is lost, either from an
external power down condition or by the failure of the power Relay Contacts supply inside of the Magnum 6K8- Switch. Useful info. about Alarm contacts:
1.There is four terminal block (1,2,3,4) provided next to AC/DC power supply
2.The top two pins (1,2) are software operated
3.The bottom two pins (3,4) are hardware operated
4.By default it is NC (normally closed)
5.The software operation needs to be enabled and set to get the Alarm traps. For detail information about the Software Alarm and software control of SNMP alarm traps, please reference the Magnum
The Alarm Contact is on the front left area (next to the DC power source) of the Magnum