Magnum 6K8-Series Industrial Field Switch

Installation and User Guide 03/06)

Once opened all the four retaining screws the front cover can be removed easily as shown in Fig 3.6.1d. on the left.

Figure 3.6.1d: Removing Face Plate

Carefully remove the PM screen plate using finger or small screw driver to come out easily as shown in Fig 3.6.1d on the right. Just be careful on the LEDs placed both side and hold the face plate tightly. There are no screws used on holding the screen face plate.

Figure 3.6.1d: Removing

PM screen Plate

3.6.2Installing 6KPM Cards in the Magnum 6K8-Series

Only one front-mounted 6KPMV Module may be installed in one Magnum 6K8-Series Field Switch unit. Follow these steps to install a 6KPMV.

Step 1. Remove top chassis cover. See procedure in Section 3.6.1 above.

Fig 3.6.2a A Magnum 6K8 unit with main board(motherboard) only

Step 2. Place Granddaughter board (as shown in fig. 3.6.2b) on the chassis built in stand off (female) provided at the front of the 6K8-Series Main Board. To place the Granddaughter board on the chassis, as shown in