Magnum 6K8-Series Industrial Field Switch

Installation and User Guide 03/06)

DC Power Supply (Options)

-48VDC Power Input Voltage : -36 to -70 VDC

24VDC Power Input Voltage : 18 to 36VDC

125VDC Power Input Voltage : 88 to 300VDC

5VDC Power Input Voltage : (+) or (-) 5%

Std. Terminal Block : “ -, GND, + ”

Power Consumption: same as for AC models, see above

For DC internal power supplies at –48VDC, 24VDC and 125VDC, including Dual Source options (for continuity of operation when either of the DC input sources are interrupted), see Appendices B and C.

Per-port MDI or MDIX on RJ-45

The copper daughter board has MDI-MDIX Auto-crossover on all the RJ-45 ports., and eliminate the use of cross-over cable between the devices. Also port-specific user settings (such as FDX or HDX, copper 10/100 speed) can be fixed using software commands.

Mountings:

Vertical mounting only Suitable for wall or DIN-Rail mounting

Agency Approvals

Magnum 6K8

UL listed (UL60950), cU, CE Emissions meet FCC Part 15 Class A

IEEE P1613 Environmental Standard for Electric Power Substations

IEEE 61850 EMC and Operating Conditions, class C for Electric Power Substations

NEMA TS-2 and TEES for traffic control equipment

Note: These products are tested and approved under IEC61850 for use in Class C sheltered locations where neither temperature nor humidity are controlled. The equipment needs to be protected against solar radiation, rainfall, other precipitations and wind. UL has not approved these products for Annex-T outdoor use.

Warranty: Three years, per UL 60950 temperature rating

Made in USA

Email sales@GarrettCom.com for details.

www . GarrettCom . com

4

Page 9
Image 9