is only to be placed across pins 5 & 6. Others are not used.

JUMPER ACROSS

DISTANCES SUPPORTED

1 - 2

0 - 10 km

3 - 4

not used

5 - 6

not used

 

1

2

 

3

4

 

5

6

J1

DEFAULT

Note: Be sure to use single-mode fiber optic cable with this module. Single-mode fiber has a smaller diameter than multi-mode fiber (2/15 - 8/60 microns for single-mode, 50/125 or 62.5/125 microns for multi-mode, where xx/xx are the diameters of the core and the core plus the cladding respectively).

2.3.7RPM-DTE

The Magnum RPM -DTE is a module

 

 

equipped with a 15-pin male DTE connector

1

Partition LED

with lock posts. (The RPM -DTE is a mating

2

Receive LED

connector for the RPM -AUI which has a 15-pin

female connector and slide locks. The pin

1

assignments of the two are the same). The

Standard 15-pin male "AUI"

2

RPM -DTE card is designed to support direct

Magnum RPM-DTE

connections (no transceiver required) using AUI drop cables to any device that is equipped

with an AUI port. Examples of such devices include servers, routers, bridges, hubs, and

UNIX workstations.